Application: These cables are used in domestic location, kitchens, offices for light duties and for light portable appliances. These cables can be used in applications where extra flexibilities are required provided that there is no danger of damage.
Specification: IEC 60227, BS-6500, VDE-0250, ISIRI(607)
Construction:
1) Conductor: Soft annealed copper stranded as per class 5 of IEC 60228, VDE 0295, ISIRI 3084
2) Insulation: Polyvinyl chloride (PVC)
3) Core identification: colour
4) Assembly: Core twisted together to make a round assembly with fillers wherever necessary. 5) outer sheath: Polyvinyl chloride (PVC)
Technical data:
1) Temperature: -25°C to +70°C
2) Working voltage: 300٫300 v R.M.S
3) Conductor resistance: As per class 5 of IEC 60228, VDE 0295, ISIRI 3084
4) Test voltage: 1500 v ac for 5 minute
5) Flame retardant: Acc. IEC 60332-1