H05VC4V-F, NYSLCY

تولید کننده و صادر کننده انواع سیم و کابل مخابراتی

Application: These cables are recommended for all electrical installations in dry or humid locations. These cables are specially suitable for control purposes in machine tool manufacturing, conveyors and assembly lines subject to medium mechanical stresses for fixed or flexible installation.

Specification: IEC 60227, VDE-0250

Construction:

1) Conductor: Soft annealed copper stranded as per class 5 of IEC 60228, VDE 0295

2) Insulation: Polyvinyl chloride (PVC)

3) Core identification: Black with white numbered. Cables with three or more cores shall have onecore

coloured green٫yellow.

4) Assembly: The cores twisted together, if necessary in several concentric layers. The assembly is covered with a polyester binder if necessary.

5) Inner sheath: Polyvinyl chloride (PVC). Colour can be supplied on request.

6) Screening: braiding of soft copper wire with 85% coverage.

7) Outer sheath: Polyvinyl chloride PVC, Colour can be supplied on request.

Technical data:

1) Temperature: -25°C to +70°C

2) Working voltage: 300٫300 v R.M.S

3) Conductor resistance: As per class 5 of VDE 0295, IEC 60228

4) Test voltage: 2000 v ac for 5 minute

5) Flame retardant: Acc. IEC 60332-1