Simbaf Cable Power Telephon
Hotline
(+98) 21 8831 6486

N2XRY

Tue, 09/17/2013 - 12:55 -- admin
N2XRY

1) Conductor: Soft annealed copper  as per class 1 or 2 of  IEC 60228, ISIRI 3084
2) Insulation: Cross-linked polyethylene (XLPE)
3) Core identification: colour up to 4 core and black with number printing for 5 core and above.
4) Inner covering: Extruded (PVC) compatible with the operating temperature of the conductor. In sector cables the core covered with one or two layer polypropylene tape.
5) Armour: Aluminum wire armour for single core and Galvanized steel wire armour for multi core
6) Outer sheath: Polyvinyl chloride (PVC). Colour can be supplied on request.

 

N2XRY
Application
These cables can be used indoors or outdoors in cable ducts, cable trays, conduits for underground location under mechanical stress at the power and switching stations, local distribution systems, industrial plants and commercial buildings.
Construction
1) Conductor: Soft annealed copper  as per class 1 or 2 of  IEC 60228, ISIRI 3084
2) Insulation: Cross-linked polyethylene (XLPE)
3) Core identification: colour up to 4 core and black with number printing for 5 core and above.
4) Inner covering: Extruded (PVC) compatible with the operating temperature of the conductor. In sector cables the core covered with one or two layer polypropylene tape.
5) Armour: Aluminum wire armour for single core and Galvanized steel wire armour for multi core
6) Outer sheath: Polyvinyl chloride (PVC). Colour can be supplied on request.
Specification IEC 60502, ISIRI 3569
Technical data
1) Temperature: -25oC to +90oC
2) Maximum short circuit temperature: 250oC (5 seconds Max.)  
3) Working voltage: 0.6/1.0 kv
4) Conductor resistance: As per 2 of IEC 60228 or ISIRI 3084
5) Test voltage: 3.5kv rms or 8.4 kvdc for 5 minutes
6) Flame retardant: Acc. IEC 60332-1
* N2XCYRY code can be supplied on request
More Info

SINGLE CORE

Approx.

weight

Approx.

Overall

diameter

Outer

armour

Thickness

Armour

Wire

diameter

Insulation

thickness

No.

strand x

diameter

Size

Kg/Km

mm

mm

mm

mm

N × d mm

mm2

 

280

11.8

1.8

0.9

0.7

7×0.85

1×4 rm

 

316

12.3

1.8

0.9

0.7

7×1.04

1×6 rm

 

386

13.3

1.8

0.9

0.7

7×1.35

1×10 rm

 

360

14.2

1.8

0.9

0.7

7×1.70

1×16 rm

 

480

16.0

1.8

0.9

0.9

7×2.14

1×25 rm

 

630

17.8

1.8

1.2

0.9

7×2.52

1×35 rm

 

770

18.9

1.8

1.2

1.0

19×1.78

1×50 rm

 

1040

21.5

1.8

1.2

1.1

19×2.17

1×70 rm

 

1340

23.6

1.8

1.6

1.1

19×2.52

1×95 rm

 

1630

25.8

1.8

1.6

1.2

37×2.03

1×120 rm

 

2000

28.0

1.9

1.6

1.4

37×2.25

1×150 rm

 

2345

30.2

2.0

1.6

1.6

37×2.52

1×185 rm

 

3150

33.2

2.1

2.0

1.7

61×2.25

1×240 rm

 

3720

37.0

2.2

2.0

1.8

61×2.52

1×300 rm

 

4710

40.6

2.3

2.0

2.0

61×2.85

1×400 rm

 
N2XRY MULTI CORE , 0.6/1.0 Kv

Approx.

weight

Approx.

Overall

diameter

Outer

Sheath

Thickness

Armour

Wire

diameter

Insulation

thickness

No.

strand x

diameter

Size

Kg/Km

mm

mm

mm

mm

N × d mm

mm2

370

14.0

1.8

0.9

0.7

7×0.53

2×1.5 rm

510

14.8

1.8

0.9

0.7

7×0.67

2×2.5 rm

420

16.0

1.8

0.9

0.7

7×0.85

2×4 rm

670

17.5

1.8

1.2

0.7

7×1.04

2×6 rm

820

18.5

1.8

1.2

0.7

7×1.35

2×10 rm

1040

20.5

1.8

1.2

0.7

7×1.70

2×16 rm

1540

24.5

1.8

1.6

0.9

7×2.14

2×25 rm

1980

28.0

1.8

1.6

0.9

7×2.52

2×35 rm

2400

31.2

1.9

1.6

1.0

19×1.78

2×50 rm

3460

36.6

2.1

2.0

1.1

19×2.17

2×70 rm

360

13.7

1.8

0.9

0.7

7×0.53

3×1.5 rm

450

15.1

1.8

0.9

0.7

7×0.67

3×2.5 rm

620

17.0

1.8

1.2

0.7

7×0.85

3×4 rm

770

18.4

1.8

1.2

0.7

7×1.04

3×6 rm

940

20.0

1.8

1.2

0.7

7×1.35

3×10 rm

1220

22.5

1.8

1.2

0.7

7×1.70

3×16 rm

1820

25.5

1.8

1.6

0.9

7×2.14

3×25 rm

2330

29.4

1.9

1.6

0.9

7×2.52

3×35 rm

2540

31.2

2.0

1.6

1.0

19×1.83

3×50 sm

3630

35.5

2.1

2.0

1.1

19×2.22

3×70 sm

4490

38.5

2.2

2.0

1.1

19×2.57

3×95 sm

5350

41.0

2.3

2.0

1.2

37×2.08

3×120 sm

6840

47.0

2.5

2.5

1.4

37×2.30

3×240 sm

8220

52.0

2.6

2.5

1.6

37×2.57

3×185 sm

10260

57.5

2.8

2.5

1.7

61×2.30

3×150 sm

12370

63.0

3.0

2.5

1.8

61×2.57

3×300 sm

15390

71.0

3.2

2.5

2.0

61×2.90

3×400 sm

N2XRY MULTI CORE 0.6/1.0 Kv

Approx.

weight

Approx.

Overall

diameter

Outer

Sheath

Thickness

Armour

Wire

diameter

Insulation

thickness

No.

strand x

diameter

Size

Kg/Km

mm

mm

mm

mm

N × d mm

mm2

2030

27.0

1.8

1.6

0.9 – 0.7

7×2.14 - 7×1.70

3×25/16 rm

2740

32.2

1.9

1.6

0.9 – 0.7

7×2.52 - 7×1.70

3×35/16 rm

2820

32.4

2.0

1.6

1.0 – 0.9

19×1.83 - 7×2.14

3×50/25 sm

3930

36.5

2.1

2.0

1.1 – 0.9

19×2.22 - 7×2.52

3×70/35 sm

5000

40.5

2.2

2.0

1.1 – 0.9

19×2.57 - 19×1.83

3×95/50 sm

6110

43.5

2.3

2.0

1.2 – 1.1

37×2.08 - 19×2.22

3×120/70 sm

7570

49.0

2.5

2.5

1.4 – 1.1

37×2.30 - 19×2.22

3×150/70 sm

9220

53.5

2.7

2.5

1.6 – 1.1

37×2.57 - 19×2.57

3×185/95 sm

11470

58.5

2.8

2.5

1.7 – 1.2

61×2.30 - 37×2.08

3×240/120 sm

13930

64.5

3.0

2.5

1.8 – 1.4

61×2.57 - 37×2.30

3×300/150 sm

17320

73.0

3.3

2.5

2.0 – 1.6

61×2.90 - 37×2.57

3×400/185 sm

N2XRY, 0.6/1.0 Kv

Approx.

weight

Approx.

Overall

diameter

Outer

Sheath

Thickness

Armour

Wire

diameter

Insulation

thickness

No.

strand x

diameter

Size

Kg/Km

mm

mm

mm

mm

N
×
d mm

mm2

455

15.4

1.8

0.9

0.7

7×0.53

4×1.5 rm

516

16.0

1.8

0.9

0.7

7×0.67

4×2.5 rm

720

18.2

1.8

1.2

0.7

7×0.85

4×4 rm

860

19.6

1.8

1.2

0.7

7×1.04

4×6 rm

1210

22.5

1.8

1.6

0.7

7×1.35

4×10 rm

1620

25.0

1.8

1.6

0.7

7×1.70

4×16 rm

2160

27.8

1.8

1.6

0.9

7×2.14

4×25 rm

2780

32.2

2.0

1.6

0.9

7×2.52

4×35 rm

3040

33.2

2.0

1.6

1.0

19×1.83

4×50 sm

4300

37.0

2.2

2.0

1.1

19×2.22

4×70 sm

5430

41.0

2.3

2.0

1.1

19×2.57

4×95 sm

6560

43.5

2.4

2.0

1.2

37×2.08

4×120 sm

8300

50.0

2.6

2.5

1.4

37×2.30

4×150 sm

9980

56.5

2.7

2.5

1.6

37×2.57

4×185 sm

12780

63.9

3.0

2.5

1.7

61×2.30

4×240 sm

15490

70.2

3.2

2.5

1.8

61×2.57

4×300 sm

20260

81.5

3.4

3.15

2.0

61×2.92

4×400 sm

Approx.

weight

Approx.

Overall

diameter

Outer

Sheath

Thickness

Armour

Wire

diameter

Insulation

thickness

No.

strand x

diameter

Size

Kg/Km

mm

mm

mm

mm

N
×
d mm

mm2

 

560

16.5

1.8

1.2

0.7

7×0.53

5×1.5 rm

 

620

17.0

1.8

1.2

0.7

7×0.53

7×1.5 rm

 

790

20.4

1.8

1.2

0.7

7×0.53

10×1.5 rm

 

870

21.0

1.8

1.2

0.7

7×0.53

12×1.5 rm

 

925

24.2

1.8

1.2

0.7

7×0.53

14×1.5 rm

 

1260

21.5

1.8

1.6

0.7

7×0.53

19×1.5 rm

 

1480

27.2

1.8

1.6

0.7

7×0.53

24×1.5 rm

 

1680

28.7

1.9

1.6

0.7

7×0.53

30×1.5 rm

 

1940

30.5

1.9

1.6

0.7

7×0.53

37×1.5 rm

 

2070

32.2

2.0

1.6

0.7

7×0.53

40×1.5 rm

 

Approx.

weight

Approx.

Overall

diameter

Outer

Sheath

Thickness

Armour

Wire

diameter

Insulation

thickness

No.

strand x

diameter

Size

Kg/Km

mm

mm

mm

mm

N
×
d mm

mm2

 

670

17.8

1.8

1.2

0.7

7×0.67

5×2.5 rm

 

760

18.6

1.8

1.2

0.7

7×0.67

7×2.5 rm

 

1124

23.0

1.8

1.6

0.7

7×0.67

10×2.5 rm

 

1210

23.8

1.8

1.6

0.7

7×0.67

12×2.5 rm

 

1316

24.3

1.8

1.6

0.7

7×0.67

14×2.5 rm

 

1590

26.4

1.8

1.6

0.7

7×0.67

19×2.5 rm

 

1880

30.0

1.9

1.6

0.7

7×0.67

24×2.5 rm

 

2126

31.8

2.0

1.6

0.7

7×0.67

30×2.5 rm

 

2710

34.5

2.1

2.0

0.7

7×0.67

37×2.5 rm

 

2890

36.2

2.2

2.0

0.7

7×0.67

40×2.5 rm

 

 

Tags: